Revisions to Engineering Standard Job Sheets
and Standard Details
Concrete
This section of the New York NRCS Conservation Engineering web page provides
explanations of the revisions to Standard Job Sheets and Standard Details.
May 3, 2006
Job Sheets
NY-ENG-JS101-1A through NY-ENG-JS101-6C, Concrete Pad, have been
replaced by Job Sheets
NY-ENG-700A through NY-ENG-700O, Concrete Slab. Several revisions have
been made.
NY Bulletin NY180-06-05
has been issued as a result of the revisions.
|
Explanation of Revisions |
|
NY-ENG-700A Released
May 2006 to replace NY-ENG-JS101-1A, with the following revisions:
- Contraction joint revised to construction joint.
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700B Released
May 2006 to replace NY-ENG-JS101-1B, with the following revisions:
- Contraction joint revised to construction joint.
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700C Released
May 2006 to replace NY-ENG-JS101-2A, with the following revisions:
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Contraction joint depth corrected to 1 ¼ ".
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700D Released
May 2006 to replace NY-ENG-JS101-2B, with the following revisions:
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700E Released
May 2006 to replace NY-ENG-JS101-3A, with the following revisions:
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Contraction joint depth corrected to 1 ¼ ".
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700F Released
May 2006 to replace NY-ENG-JS101-3B, with the following revisions:
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Contraction joint depth corrected to 1 ¼ ".
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700G Released
May 2006 to replace NY-ENG-JS101-4A, with the following revisions:
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700H Released
May 2006 to replace NY-ENG-JS101-4B, with the following revisions:
- Construction Specifications and Notes, Item 4: Minimum protective
cover from earth surfaces or from gravel subbase revised to 2 ½
inches.
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Construction Specifications and Notes, Item 11 added: Variation of
NRCS New York Specification (01)
Concrete 832 , minimum protective cover from
earth surfaces, as per New
York Bulletin NY210-05-01, dated January 19, 2005
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700I Released
May 2006 to replace NY-ENG-JS101-4C, with the following revisions:
- Typographical error in titleblock corrected. 5 inches changed to 6
inches.
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Welded wire fabric sheet changed from W2.9xW.29 to W7xW7
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700J Released
May 2006 to replace NY-ENG-JS101-5A, with the following revisions:
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700K Released
May 2006 to replace NY-ENG-JS101-5B, with the following revisions:
- Construction Specifications and Notes, Item 4: Minimum protective
cover from earth surfaces or from gravel subbase revised to 2 ½
inches.
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Construction Specifications and Notes, Item 11 added: Variation of
NRCS New York Specification (01)
Concrete 832 , minimum protective cover from
earth surfaces, as per New
York Bulletin NY210-05-01, dated January 19, 2005
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700L Released
May 2006 to replace NY-ENG-JS101-5C, with the following revisions:
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Welded wire fabric sheet changed from W2.9xW.29 to W7xW7
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700M Released
May 2006 to replace NY-ENG-JS101-6A, with the following revisions:
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700N Released
May 2006 to replace NY-ENG-JS101-6B, with the following revisions:
- Contraction joint revised to construction joint.
- Construction Specifications and Notes, Item 4: Minimum protective
cover from earth surfaces or from gravel subbase revised to 2 ½
inches.
- Construction Specifications and Notes, Item 5: Expansion joints
revised to Isolation joints.
- Construction Specifications and Notes, Item 10 added: Variation of
NRCS New York Specification (01)
Concrete 832 , minimum protective cover from
earth surfaces, as per New
York Bulletin NY210-05-01, dated January 19, 2005
- Conditions for Use statement added.
- Slab design loading data added.
|
|
NY-ENG-700O Released
May 2006 to replace NY-ENG-JS101-6C, with the following revisions:
- Contraction joint revised to construction joint.
- Construction Specifications and Notes, Item 4: Expansion joints
revised to Isolation joints.
- Welded wire fabric sheet changed from W2.9xW.29 to W7xW7
- Conditions for Use statement added.
- Slab design loading data added.
|